JavaScript is disabled for your browser. Some features of this site may not work without it.
  • Nos collections

    • Rapports d'expertise collectiveLes Cahiers du Comité pour l'histoire de l'InsermArchives et patrimoine numériqueRevue médecine/sciencesInserm magazineLes Dossiers Sciences et société
  • Parcourir

    • Tout iPubliCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets
  • Mon compte

    • Ouvrir une session
  • Rapport d'activité

    • Publications les plus consultéesStatistiques par paysAuteurs les plus consultés
  • Lexique iPubli

  Accueil iPubli 
  •   Accueil iPubli
  • Revue médecine/sciences
  • médecine/sciences 2016 - Volume 32
  • MS 2016 num. 08-09
  • Voir le document
  •   Accueil iPubli
  • Revue médecine/sciences
  • médecine/sciences 2016 - Volume 32
  • MS 2016 num. 08-09
  • Voir le document
Ecoutez
Lexique de ce document Lexique de ce document
TermeDéfinition

En savoir plus

  • Bref historique
  • Site de l'éditeur EDP Sciences

La cryo-microscopie, une alternative à la cristallographie aux rayons X ?

Thumbnail
Date
2016
Auteur
Boutin, Jean A.
Li, Zhuolun
Vuillard, Laurent
Vénien-Bryan, Catherine
Voir/Ouvrir
MS_2016_08-09_758.pdf (3.748Mo)
MS_2016_08-09_758.html (98.25Ko)
Metadata
Afficher la notice complète
Résumé
De récentes avancées technologiques révolutionnent le domaine des biologistes structuralistes. Plus précisément, des progrès spectaculaires liés au développement de nouvelles technologies de capture d’images de microscope électronique (la détection directe d’électrons) ainsi que la mise à disposition de nouveaux logiciels d’analyse d’images ont conduit à une percée en terme de résolution en cryo-microscopie électronique à transmission. Il est ainsi possible de calculer relativement rapidement des structures à haute résolution de molécules biologiques dont l’étude résiste aux méthodes plus classiques comme la diffraction des rayons X ou la résonance magnétique nucléaire (RMN). Ces structures ainsi obtenues peuvent aussi venir en complément des informations structurales déjà décrites par d’autres méthodes. Certaines de ces nouvelles structures résolues grâce à la cryo-microscopie électronique révèlent pour la première fois le fonctionnement précis de mécanismes essentiels au bon déroulement physiologique d’une cellule. La capacité à résoudre ces structures à la résolution du détail atomique est une condition essentielle pour le développement de nouveaux médicaments ayant comme cible thérapeutique ces protéines d’intérêt. Grâce à ces avancées techniques que nous résumons ici, des questions biologiques et médicales sont maintenant devenues accessibles, ce qui était inconcevable il y a seulement cinq ans.
 
Recent technological advances have revolutionized the field of structural biologists. Specifically, dramatic progress related to the development of new electron microscopes and image capture (direct electron detection camera) and the provision of new image analysis software has led to a breakthrough in terms of resolution attained using cryo-electron transmission microscopy. It is thus possible to calculate relatively quickly high-resolution structures of biological molecules whom structural study still resists to more conventional methods such as X-ray diffraction or nuclear magnetic resonance (NMR). These structures thus obtained may also bring complementary structural information to those already described by other methods. Some of these new structures resolved through cryo-electron microscopy revealed for the first time the precise operation of essential mechanisms necessary for the good physiological process of a cell. The ability to solve these structures at atomic resolution detail is essential for the development of new drugs that target these proteins of therapeutic interest. Thanks to these advanced techniques that we summarize in this revew, biological and medical issues have now become accessible, whereas this approach was inconceivable only five yeras ago. ‡
 
Pour citer ce document
Boutin, Jean A. ; Li, Zhuolun ; Vuillard, Laurent ; Vénien-Bryan, Catherine ; La cryo-microscopie, une alternative à la cristallographie aux rayons X ?, Med Sci (Paris), , Vol. 32, N° 8-9 ; p. 758-767 ; DOI : 10.1051/medsci/20163208025
URI
http://hdl.handle.net/10608/8949
Collections
  • MS 2016 num. 08-09
Recherche avancée

Nos collections

Rapports d'expertise collectiveLes Cahiers du Comité pour l'histoire de l'InsermArchives et patrimoine numériqueRevue médecine/sciencesInserm magazineLes Dossiers Sciences et société

Parcourir

Tout iPubliCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une session

Rapport d'activité

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés
Lexique iPubli
 
Sites du DSO (département Science Ouverte) :
  • Insermbiblio
  • MeSH bilingue
  • HAL-Inserm
Nos partenaires :
  • Service des archives de l'Inserm
  • Délégation Régionale Inserm Auvergne Rhône Alpes
Contact | Mentions légales | A propos | Accessibilité (non conforme)
Institut national de la santé et de la recherche médicale - 101, rue de Tolbiac | 75654 Paris Cedex 13
 

 

 
Sites du DSO (département Science Ouverte) :
  • Insermbiblio
  • MeSH bilingue
  • HAL-Inserm
Nos partenaires :
  • Service des archives de l'Inserm
  • Délégation Régionale Inserm Auvergne Rhône Alpes
Contact | Mentions légales | A propos | Accessibilité (non conforme)
Institut national de la santé et de la recherche médicale - 101, rue de Tolbiac | 75654 Paris Cedex 13